Product Consumibles para laboratorio biológico Cultivos celulares Productos para cultivo celular y tisular CellATTACH®
内页720×540 拷贝.jpg
内页720×540 拷贝2.jpg
内页720×540 拷贝1.jpg

Productos para cultivo celular y tisular CellATTACH®

Matraces de cultivo celular y tisular: T12.5  T25  T75  T182  T225  T300
Tipo de tapón: Hermético  Con ventilación 
Placas de cultivo celular y tisular:6 pocillos   12 pocillos   24 pocillos   48 pocillos   96 pocillos 
Placas de Petri para cultivo celular y tisular: 35 mm   60 mm   70 mm   90 mm   100 mm   150 mm 

Obtenga una cotización
Introducción
Información del producto
Información del pedido
Preguntas frecuentes
Productos recomendados

Introducción

Información del producto

La serie de productos superhidrófilos para cultivo celular CellATTACH® se crea mediante la introducción de grupos polares en sus superficies. De este modo se forma una superficie superhidrófila duradera y estable que facilita un buen crecimiento adherente de varios tipos de células en diferentes condiciones de cultivo, mejorando así el rendimiento celular. La superficie tratada también elimina la necesidad de un recubrimiento biológico inestable, laborioso y costoso.

Características

* La exclusiva tecnología de tratamiento superhidrófilo de la superficie proporciona una mejor adherencia de las células, lo que favorece un rápido crecimiento celular y aumenta el rendimiento.
* Garantiza una adherencia celular continua y uniforme, y puede utilizarse para cultivos adherentes de células primarias, células neuronales, células madre y otras células de difícil cultivo que tienen requisitos más estrictos en cuanto a la hidrofilicidad de la superficie de cultivo.
* Las células pueden adaptarse rápidamente a un entorno de cultivo sin suero o con bajo contenido en suero, con lo que se satisfacen las necesidades de los experimentos que exigen la eliminación de la interferencia que suponen los componentes del suero o que precisan niveles reducidos de suero, disminuyendo así el coste del cultivo celular.




Materiales

* Cuerpo del matraz/placa/placa de Petri: Poliestireno (PS)
* Tapón del matraz: Polietileno de alta densidad (HDPE)
* Membrana de filtración: Politetrafluoroetileno (PTFE)
* Conforme a las normas de Clase VI de la USP

Información del producto

Jet Biofil ES CATÁLOGO 2024

Catálogo

Jet Biofil ES CATÁLOGO 2024

Descargar archivo

Información del pedido

Matraces de cultivo celular y tisular CellATTACH®
Cat. n.º Volumen (mL) Volumen de trabajo (mL) Volumen de trabajo Máximo (mL) Volumendetrabajorecomendado(mL) Tipo de tapón Largo (mm) Ancho (mm) Alto(mm) Estéril Cant.porbolsa Cant.porpaquete
CAF011025 25 12.5 8.0 2.5 - 3.8 Hermético 73.7 40.4 22.8 10 200
CAF012025 25 12.5 8.0 2.5 - 3.8 Con ventilación 73.7 40.4 22.8 10 200
CAF011050 50 25.0 17.5 5.0 - 7.5 Hermético 92.9 49.5 29.1 10 200
CAF012050 50 25.0 17.5 5.0- 7.5 Con ventilación 92.9 49.5 29.1 10 200
CAF011250 250 75.0 60.0 15.0 - 22.5 Hermético 152.5 81.5 35.2 5 100
CAF012250 250 75.0 60.0 15.0 - 22.5 Con ventilación 152.5 81.5 35.2 5 100
CAF011600 600 182.0 125.0 36.4 - 54.6 Hermético 219.3 115.7 38.3 5 40
CAF012600 600 182.0 125.0 36.4 - 54.6 Con ventilación 219.3 115.7 38.3 5 40
CAF111600 600 182.0 (extendido) 200.0 36.4 - 54.6 Hermético 219.3 115.7 49.5 5 40
CAF112600 600 182.0(extendido) 200.0 36.4 - 54.6 Con ventilación 219.3 115.7 49.5 5 40
CAF011850 850 300.0 200.0 60.0 - 90.0 Hermético 269.2 116.0 47.0 3 18
CAF012850 850 300.0 200.0 60.0 - 90.0 Con ventilación 269.2 116.0 27.0 3 18


Placas de Petri para cultivo celular y tisular CellATTACH®

Cat. n.º Diámetro (mm) Altura(mm) Volumende trabajo
recomendado(mL)
Área de
crecimiento
celular (cm²)
Cant.porbolsa Cant.porpaquete
CAD010035 35 12.6 2-3.5 8.5 10 240
CAD010060 60 17.3 4-7 21.2 10 240
CAD010070 70 15.5 6-11 36.3 10 240
CAD010090 90 16.9 10-18 55.0 10 240
CAD010100 100 22.6 12-20 60.8 10 240
CAD010150 150 22.7 25-50 143.0 5 80


Placas de cultivo celular y tisular CellATTACH®
Cat. n.º Cant. de pocillos Tipo de superficie Volumen de trabajo Máximo (mL) Volumendetrabajo
recomendado(mL)
Cant. por caja Cant.porpaquete
CAP011006 6 Plano 17.0 1.90~2.90 1 100
CAP011012 12 Plano 6.8 0.76~1.14 1 100
CAP011024 24 Plano 3.5 0.38~0.57 1 100
CAP011048 48 Plano 1.6 0.19~0.29 1 100
CAP011096 96 Plano 0.3 0.08~0.20 1 100
CAP012096 96 En U 0.3 0.08~0.20 1 100

Preguntas frecuentes

FAQ about cell culture plates/bottles/dishes

* What does TC-treated in the product name mean?

TC-treated means that Tissue Cultured is used to treat the surface. By means of corona discharge or gas plasma, Jet Biofil can improve the hydrophilicity of polystyrene (PS) surface, improve the adhesion of proteins needed for cell adhesion, and thus help cells adhere to the wall.

 

* Which surface should I use to culture suspension cells?

The suspension cells do not have the need for cell adhesion, and generally the culture supplies for untreated surface can be used. TC-treated surface can also culture suspension cells, but according to the state and type of cells, some cells may appear adhesion phenomenon.

 

* If I want to coat extracellular matrix myself, what kind of surface should I use?

You can choose the culture vessel with untreated surface to coat the extracellular matrix by yourself. Of course, in this case, vessels with TC-treated surface can also be used

 

* How to use the cell culture bottle with a sealed cap? What are the differences between the use of cell culture bottles with filter membrane caps?

Cell culture bottles with sealed caps provide a closed cell culture environment. If it is needs to connect with the air in the incubator, it is necessary to slightly loosen the cap after the bottle is put into the incubator to allow air to enter. Similarly, when taking out the bottle, tighten the cap first and then take it out. The cap with the filter membrane itself has the function of breathable, and the filter membrane can prevent microbial contamination. Therefore, the cap of the culture bottle can be directly tightened and put into the incubator during use, but it needs to be noted that the filter membrane on the cap cannot be wet, wet filter membrane cannot ensure the passage of gas.

 

* What does T25, T175 mean that I often hear?

Taking T25 as an example, it refers to a cell culture bottle with a growth surface area of 25 cm2. According to the type of bottle cap and different culture surfaces, different article numbers correspond to different products.

 

* I bought the product with article number xxxxxx. What is its growth area? How much medium should I add to culture my cells?

We recommend using 0.2-0.3mL/cm2 of medium

 

* The cell culture bottle/dish I bought is not vacuum packed. The bag looks loose. Is there a quality problem?

The cell culture supplies of Jet Biofil are not vacuum packed, and are only manually aspirated for convenient transportation, so there will be differences. In addition, the temperature and air pressure in different regions will also affect the tightness of the packaging. If there is no air leakage in the package and the cap does not fall off from the product, it will not affect the sterility of the product and the quality of the product. Please feel relieved the use. If the package is damaged or the air leaks or the cover falls off from the product, please take a photo and submit a complaint through your dealer. At the same time, please pay attention to provide a photo of the outer box of the product. When you receive the goods, please carefully confirm whether the outer box is damaged or deformed.

 

* I can’t use up a package of culture supplies in one experiment. How should I preserve it?

We cannot guarantee the sterility of the product after opening. We suggest that you store it in a sterile environment, control the temperature and humidity of the environment, and avoid the storage under light/ultraviolet irradiation.

 

* I used the culture bottle/dish/plate of Jet Biofil, and the cells did not adhere to the wall. Is it a product quality problem?

There are many factors that lead to non-adherent cells, such as culture medium composition and pH value, culture environment, digestion operation, cell type, cell passage, etc. If you use the same product with the same article number to culture the same cell strain for a long time, and the cells adhere normally before, but do not adhere to the wall now, it is recommended that you timely record the batch number of the products used in both cases, and conduct repeated parallel experiments, that is, use cells from the same source to spread on the supplies of these two batches for culture (pay attention to using the culture medium from the same source). Culture in the same incubator to determine the main reason why cells do not adhere to the wall.

 

* The color of the culture bottle/dish/plate I bought this time is more yellow than that of last time. Is it a product quality problem?

It is normal that plastic consumables of different batches may turn yellow after irradiation sterilization.


Preguntas frecuentes

Productos recomendados

Volver a la página anterior